Submit RFQ
Bürkert Type 8098 FLOWave hygienic SAW flowmeter

Bürkert Type 8098 FLOWave SAW Flowmeter

Bürkert

Model / Part Number: Type 8098 FLOWave

Availability subject to quotation and stock confirmation

Supplied for maintenance, retrofit and replacement projects. Exact suffix, configuration and condition must be confirmed before ordering.

pcsRequest a Quote
WhatsApp InquiryResponse within 1 business day
BrandBürkert
Model / Part NumberType 8098 FLOWave
Country of OriginConfirm by lot

FURUYA DENKI is an independent supplier and is not affiliated with or authorized by the brands shown on this page. Brand names, trademarks and part numbers are used for identification only. Availability, specifications, condition, origin, documentation, lead time and warranty are subject to our formal quotation. Please verify all technical requirements before ordering. Images are for reference only.

▣ Product Overview

The Bürkert Type 8098 FLOWave is part of the FLOWave product range and is based on SAW (Surface Acoustic Waves) technology. It is mainly designed for applications with the highest hygienic demands. The use of suitable stainless steel materials, a measuring tube completely free of internal parts and a hygienic external design helps ensure reliable measurement and easy cleaning in hygienic processes.

Type 8098 offers important practical advantages such as compact dimensions, lightweight construction, easy installation and simple handling. It is suitable for measuring homogeneous liquids that are free of air and solid particles. For liquids with higher viscosity, integrated viscosity compensation can be activated to improve measurement performance. Gas and steam cannot be measured by this device.

In addition to volume flow measurement, an optional density measurement function is available. With this option, the device can calculate mass flow based on volume flow and density. Additional derived process values such as differentiation factor (DF), acoustic transmission factor and concentration can provide further information about the liquid in use.

The FLOWave design has no obstacles inside the measuring tube and is compliant with hygienic requirements. It is CIP/SIP compatible and is especially suitable for liquids with low or no conductivity, such as water for injection (WFI). Digital communication options include Bürkert system bus (büS)/CANopen, Modbus TCP, PROFINET, EtherNet/IP, EtherCAT and IO-Link. Parameterisation can be carried out via Bürkert Communicator and the integrated display. Optional approvals such as ATEX/IECEx and other hazardous area certifications are also available depending on configuration.

⚙ Technical Specifications

Measurement PrincipleSAW (Surface Acoustic Waves)
Measured MediumHomogeneous liquids, free of air/gas bubbles and suspended solids
Nominal SizeDN 08 to DN 80
Process ConnectionClamp / Aseptic flange, depending on configuration
Fluid Temperature-20 to +110 °C
Sterilization TemperatureUp to +140 °C for max. 60 min °C
Operating PressureUp to PN 25, depending on size and connection
Volume Flow Accuracy±0.4% of measured value at ≥1 m/s
Repeatability±0.2% of measured value at ≥1 m/s
Operating Voltage12 to 35 V DC
Measuring Tube MaterialStainless steel 316L / 1.4435
CIP / SIP CompatibilityYes
Digital CommunicationbüS/CANopen, Modbus TCP, PROFINET, EtherNet/IP, EtherCAT, IO-Link
Optional MeasurementsDensity, mass flow, concentration and additional process values
Hygienic DesignYes

▦ Typical Applications

  • Food & Beverage
  • Pharmaceutical & Biotech
  • Water for Injection (WFI)
  • Purified Water (PW)
  • Laboratory & Process Systems

▰ Availability & Delivery

Availability & DeliveryAvailability subject to quotation and stock confirmation
Lead TimeAvailability and lead time depend on the selected pipe size, process connection, communication interface, certifications and optional functions. Please contact us with your detailed application requirements for current availability and delivery confirmation.
Shipping OptionsAir freight, sea freight, express
PackagingSecure export packaging

? FAQ

What is the Bürkert Type 8098 FLOWave used for?

The Bürkert Type 8098 FLOWave is designed for accurate measurement of liquid flow in hygienic process applications such as food and beverage, pharmaceutical, biotechnology, purified water and water-for-injection systems.

What measurement technology does Type 8098 FLOWave use?

Type 8098 FLOWave uses SAW (Surface Acoustic Waves) technology. The measuring tube contains no internal measuring elements, helping provide a hygienic design, easy cleaning and low pressure loss.

Is Bürkert Type 8098 FLOWave suitable for CIP and SIP processes?

Yes. Type 8098 FLOWave is designed for hygienic applications and is suitable for CIP and SIP processes, making it well suited for food, beverage, pharmaceutical and biotechnology installations.

Yes. FLOWave can measure liquids with low or no electrical conductivity, including applications such as purified water and water for injection (WFI). The liquid should be homogeneous and ideally free of gas bubbles and solid particles.

Yes. FLOWave can measure liquids with low or no electrical conductivity, including applications such as purified water and water for injection (WFI). The liquid should be homogeneous and ideally free of gas bubbles and solid particles.

What communication interfaces are available for Bürkert Type 8098?

Depending on the selected configuration, Type 8098 supports digital communication options including büS/CANopen, Modbus TCP, PROFINET, EtherNet/IP, EtherCAT and IO-Link.