LAMTEC 650R0031 LS1 Zirconium-Dioxide Lambda Oxygen Probe for LT1

LAMTEC

Model / Part Number: LS1 / 650R0031

Availability subject to quotation and stock confirmation

Supplied for maintenance, retrofit and replacement projects. Exact suffix, configuration and condition must be confirmed before ordering.

pcsRequest a Quote
WhatsApp InquiryResponse within 1 business day
BrandLAMTEC
Model / Part NumberLS1 / 650R0031
Country of OriginConfirm by lot

Independent supplier; model, suffix, condition and availability require confirmation.

▣ Product Overview

The LAMTEC LS1, part number 650R0031, is a heated zirconium-dioxide lambda probe for continuous oxygen measurement with the LAMTEC LT1 Lambda Transmitter. The complete LS1/LT1 system measures O₂ in combustion and process gases in the superstoichiometric range, λ > 1.

The LAMTEC LS1 650R0031 is a heated zirconium-dioxide lambda probe used with the LAMTEC LT1 Lambda Transmitter for continuous measurement of oxygen concentration in combustion flue gases, furnace atmospheres and suitable process gases in the superstoichiometric range, λ > 1.

In the complete LT1/LS1 measuring system, a small amount of measuring gas is drawn through a capillary tube to the heated ZrO₂ measuring cell. The probe is connected to the LT1 through the appropriate probe cable and gas hose. The LT1 evaluates the probe signal, performs automatic calibration using ambient air at approximately 20.96 vol.% O₂ and automatically compensates for ageing of the measuring cell.

The complete system covers an O₂ measuring range of 0 to 21 vol.% and can achieve an accuracy of ±0.1 vol.% O₂ after calibration. With the appropriate 450 mm gas extraction device, the published system response time is below 15 seconds to 90% of the final value. The LS1 probe protection rating is IP42.

LS1 probes are available in plug-in, flange, immersion, high-dust and high-temperature configurations. Permitted flue-gas temperature, pressure, dust loading, probe length and fuel compatibility depend on the exact installation arrangement. Standard LS1 arrangements can measure directly in moist flue gas up to approximately 600 °C, while specially configured ceramic high-temperature extraction systems can be used at temperatures up to 1400 °C.

Part number 650R0031 identifies the probe, not a complete oxygen analyser. The LT1 transmitter, probe installation fitting, gas extraction device, cable, hose, calibration equipment and other accessories must be confirmed separately.

⚙ Technical Specifications

Specification 1LAMTEC
Specification 2LS1
Specification 3650R0031
Specification 4Heated lambda oxygen probe
Specification 5Zirconium dioxide, ZrO2
Specification 6LAMTEC LT1 Lambda Transmitter
Specification 7Oxygen, O2
Specification 80 to 21 vol.% O2
Specification 9Superstoichiometric gases, lambda greater than 1
Specification 10±0.1 vol.% O2
Specification 11Ambient air, approximately 20.96 vol.% O2
Specification 12Less than 15 seconds to 90% with 450 mm gas extraction device
Specification 13IP42
Specification 14Up to approximately 600 °C, configuration dependent
Specification 15Up to 1400 °C with suitable ceramic extraction system
Specification 16Performed by compatible LT1 system
Specification 17Automatic ZrO2 cell ageing compensation by LT1
Specification 181
Specification 190.5 l/h
Specification 207-wire probe cable and gas hose, configuration dependent
Specification 21Combustion flue gas, furnace atmosphere and suitable process gas
Specification 22No
Specification 23Not confirmed
Specification 24Not confirmed