Thermo Scientific (Orion Product Line)

Model / Part Number: 087010MD

Availability subject to quotation and stock confirmation

Supplied for maintenance, retrofit and replacement projects. Exact suffix, configuration and condition must be confirmed before ordering.

pcsRequest a Quote
WhatsApp InquiryResponse within 1 business day
BrandThermo Scientific (Orion Product Line)
Model / Part Number087010MD
Product TypeRDO Optical Dissolved Oxygen Electrode -
Country of OriginConfirm by lot

FURUYA DENKI is an independent supplier and is not affiliated with or authorized by the brands shown on this page. Brand names, trademarks and part numbers are used for identification only. Availability, specifications, condition, origin, documentation, lead time and warranty are subject to our formal quotation. Please verify all technical requirements before ordering. Images are for reference only.

▣ Product Overview

Thermo Scientific Orion 087010MD is an RDO optical dissolved oxygen electrode designed for accurate and low-maintenance dissolved oxygen measurement in laboratory and field water quality applications.

The probe uses optical luminescence-based RDO technology rather than a traditional electrochemical membrane system. This eliminates the need for membrane replacement, filling solution and probe warm-up before measurement.

The dissolved oxygen concentration range is 0.00 to 20.0 mg/L, while the saturation measurement range is 0.0 to 200%.

RDO technology helps minimize thermal shock and common measurement interferences, supporting stable measurements in demanding water and wastewater applications.

The replaceable RDO optical cap is monitored by an internal sensor clock. Once a new cap is installed, the probe tracks its 365-day service life.

The 087010MD version is supplied with a 3 m cable and is intended for use with compatible Thermo Scientific Orion Star meters equipped with RDO input.

The probe is suitable for wastewater, environmental monitoring, aquaculture, industrial water, research and general field water quality testing.

The 087010MD system is compatible with replacement RDO cap 087001, stainless steel protective guard 087002 and calibration sleeve 087003.

Key Features:
• Optical RDO dissolved oxygen technology
• No membrane replacement required
• No filling solution required
• No probe warm-up required
• DO concentration range: 0.00 to 20.0 mg/L
• DO saturation range: 0.0 to 200%
• 3 m cable
• Replaceable optical RDO cap
• 365-day RDO cap life tracking
• Suitable for laboratory and field measurements
• Compatible with Orion Star meters with RDO input
• Suitable for wastewater and environmental applications

⚙ Technical Specifications

Parameter NameParameter Value Unit
BrandThermo Scientific Orion -
Catalog Number087010MD -
Product TypeRDO Optical Dissolved Oxygen Electrode -
Probe TypeOptical Dissolved Oxygen Probe -
Sensor TechnologyRDO Optical / Luminescence -
Measurement ParametersDissolved Oxygen / % Saturation / Temperature -
DO Concentration Range0.00 to 20.0 mg/L
DO Accuracy±0.1 mg/L from 0 to 8 mg/L; ±0.2 mg/L from 8 to 20 mg/L -
DO Saturation Range0.0 to 200 %
DO Saturation Accuracy±2 %
Response Time T9030 s
Response Time T9560 s
Operating Temperature0 to 50 °C
Temperature CompensationBuilt-In -
Warm-Up TimeNot Required -
MembraneNot Required -
Filling SolutionNot Required -
Cable Length3 m
Compatible MeterOrion Star Meter with RDO Input -
RDO Cap Life365 Days
Replacement RDO Cap087001 -
Protective Guard087002 -
Calibration Sleeve087003 -
ComplianceASTM D888 / Standard Methods 4500-O G or H / ISO 17289 -
ApplicationLaboratory / Field / Wastewater / Environmental Monitoring -
Probe Warranty36 Months
RDO Cap Warranty12 Months
اسم المعلمةقيمة المعلمة الوحدة
العلامة التجاريةThermo Scientific Orion -
رقم الكتالوج087010MD -
نوع المنتجقطب RDO بصري لقياس الأكسجين المذاب -
نوع المجسمجس بصري لقياس الأكسجين المذاب -
تقنية الاستشعارRDO بصري / اللمعان -
معلمات القياسالأكسجين المذاب / نسبة التشبع / درجة الحرارة -
نطاق تركيز DO0.00 إلى 20.0 mg/L
دقة DO±0.1 mg/L من 0 إلى 8 mg/L؛ ±0.2 mg/L من 8 إلى 20 mg/L -
نطاق تشبع DO0.0 إلى 200 %
دقة تشبع DO±2 %
زمن الاستجابة T9030 s
زمن الاستجابة T9560 s
نطاق درجة حرارة التشغيل0 إلى 50 °C
تعويض درجة الحرارةمدمج -
وقت الإحماءغير مطلوب -
الغشاءغير مطلوب -
محلول التعبئةغير مطلوب -
طول الكابل3 m
الجهاز المتوافقأجهزة Orion Star المزودة بمدخل RDO -
عمر غطاء RDO365 يوم
غطاء RDO البديل087001 -
الحاجز الواقي087002 -
غطاء المعايرة087003 -
المعاييرASTM D888 / Standard Methods 4500-O G أو H / ISO 17289 -
مجال الاستخداممختبري / ميداني / مياه الصرف / المراقبة البيئية -
ضمان المجس36 شهر
ضمان غطاء RDO12 شهر

▦ Typical Applications

  • Water Quality Testing
  • Wastewater
  • Environmental Monitoring
  • Aquaculture
  • Industrial Water

▰ Availability & Delivery

Availability & DeliveryAvailability subject to quotation and stock confirmation
Lead TimeAvailability and delivery time depend on destination and order quantity. Please contact us for current stock status, lead time and replacement RDO cap availability.
Shipping OptionsAir freight, sea freight, express
PackagingSecure export packaging

? FAQ

What is Thermo Scientific Orion 087010MD used for?

The Orion 087010MD is used for dissolved oxygen measurement in water quality, laboratory, environmental monitoring, wastewater, aquaculture and field applications.

What is the dissolved oxygen range of the 087010MD?

The 087010MD provides a dissolved oxygen concentration range of 0.00 to 20.0 mg/L with a saturation range of 0 to 200%.

Does the 087010MD require a membrane or filling solution?

No. The 087010MD uses optical RDO technology and does not require a traditional membrane, filling solution or probe warm-up before measurement.

How long does the RDO cap last on the 087010MD?

The probe tracks the RDO cap service life internally, with a nominal cap life of approximately 365 days after installation.

What should be confirmed before ordering the 087010MD?

Please confirm catalog number 087010MD, compatible meter, cable length, measurement range, application conditions and replacement RDO cap requirements before ordering.