▣ Product Overview

The Rosemount 8800D is a configurable vortex flowmeter for liquid, gas and steam service. Its all-welded, gasket-free, non-clog meter body and isolated sensor reduce potential leak points and allow sensor replacement without breaking the process seal. Complete application sizing and full model-code confirmation are required before quotation.

The Rosemount 8800D is a configurable inline vortex flowmeter for homogeneous, single-phase liquid, gas and steam applications. It uses an all-welded, gasket-free, non-clog meter body and an isolated sensor that can be replaced without breaking the process seal. The series is available in flanged, wafer, reducer, weld-end, threaded, dual and quad arrangements, with multiple wetted-material and pressure-class options. Outputs include 4–20 mA/HART, scalable pulse, FOUNDATION Fieldbus and Modbus RS-485. Selected multivariable configurations provide temperature and/or pressure compensation for mass-flow measurement, while certified options support safety instrumented systems up to SIL 3. Final performance, process limits and ordering code must be established through application sizing and configuration review.

Datasheets

⚙ Technical Specifications

Measurement principleVortex shedding -
Process fluidsHomogeneous single-phase liquids, gases and steam -
Liquid volume-flow accuracy±0.65, Reynolds number above 20,000 % of rate
Gas/steam volume-flow accuracy±1.0, Reynolds number above 15,000 % of rate
Volume-flow repeatability±0.1 % of actual rate
Typical maximum turndownUp to 38:1, application dependent -
Maximum liquid velocity7.62 m/s
Maximum gas/steam velocity67.06 to 76.2, style/size dependent m/s
Flanged line size15 to 300 mm
Wafer line size15 to 200 mm
Reducer line size25 to 350 mm
Standard sensor temperature-40 to +232 °C
Extended sensor temperatureApproximately -200 to +427, material dependent °C
Severe-service sensor temperatureApproximately -200 to +450, selected configuration °C
Output options4-20 mA/HART, scalable pulse, FOUNDATION Fieldbus, Modbus RS-485 -
HART terminal voltage10.8 to 42 VDC
Maximum transmitter power1 W
Ambient temperature without LCD-50 to +85 °C
Ambient temperature with LCD-40 to +85 °C
Process connectionsFlanged, wafer, weld-end or threaded -
Available pressure classesASME Class 150-1500; EN PN10-PN250; JIS 10K-40K, option dependent -
Wetted materials316/316L stainless steel, nickel alloy, carbon steel or duplex stainless steel -
Enclosure ratingCSA Type 4X; IP66 -
Reference straight pipe35D upstream and 5D downstream for rated accuracy pipe diameters
Functional safetyIEC 61508 SIL 2 in 1oo1 / SIL 3 in 1oo2, certified configuration required -
Meter stylesFlanged, wafer, reducer, weld-end, threaded, dual and quad -
Example configured model code8800D F 020 S A1 N 1 D 1 M5 MTA Q4 Q8 -

▦ Typical Applications

  • Chemical & Petrochemical
  • Oil & Gas
  • Power Generation
  • Refining
  • Utilities

▰ Availability & Delivery

Availability & DeliveryAvailability subject to quotation and stock confirmation
Lead TimeRFQ confirmation required
Shipping OptionsAir freight, sea freight, express
PackagingSecure export packaging